5.2 Effects of temperature and pH
Your Progress on Topic 5.2
Score 5 out of 5 on the practice quiz below to master this topic.
What you will learn in 5.2
Read these goals and key words first, then continue to the lesson.
What you need to know
- Understand that you can follow an enzyme reaction by measuring how the amount of substrate goes down, or how the amount of product goes up.
- Investigate and describe how temperature and pH change enzyme activity.
- Explain these effects using the words kinetic energy, shape and fit, denaturation and frequency of effective collisions.
Key words
| Word | Meaning |
|---|---|
| Enzyme activity | How fast an enzyme works. Also called the rate of reaction. |
| Optimum | The best temperature or pH, where the enzyme works fastest. |
| Kinetic energy | Movement energy. Hotter molecules have more kinetic energy, so they move faster. |
| Effective collision | When a substrate molecule hits the enzyme's active site in a way that lets it fit and react. |
| Denatured | When an enzyme's shape has changed for good, so its active site no longer fits the substrate. It cannot work any more. |
| pH | A scale that shows how acidic or alkaline something is. Below 7 is acidic, 7 is neutral, above 7 is alkaline. |
Revision Notes: Effects of temperature and pH
How do we measure an enzyme reaction?
We cannot watch molecules, so we measure how much substrate is left, or how much product has been made, at regular times.
| Example | What we measure |
|---|---|
| Amylase breaking down starch | How long it takes for the starch to disappear (the substrate goes down). Test drops with iodine every 30 seconds. When iodine stays orange-brown, the starch has gone. |
| Catalase breaking down hydrogen peroxide | How much oxygen gas is made (a product goes up). Count the bubbles, or collect the gas in a measuring cylinder. |
The faster the substrate disappears, or the faster the product appears, the higher the enzyme activity.
The effect of temperature
Cold to warm: activity goes up
As the temperature rises:
- The enzyme and substrate molecules get more kinetic energy, so they move faster.
- They bump into each other more often. There are more effective collisions every second: the substrate fits into the active site more often.
- More enzyme-substrate complexes form, so more product is made each second.
The optimum temperature
At the optimum temperature the enzyme works fastest. For most enzymes in the human body, this is about 37 °C (body temperature).
Too hot: activity drops fast
Above the optimum:
- The enzyme molecule vibrates so much that its shape changes.
- The active site changes shape, so the substrate no longer fits.
- Fewer enzyme-substrate complexes form, so activity falls quickly.
- In the end the enzyme is denatured. This cannot be undone, even if it cools down again.
Very cold
At low temperatures enzymes work slowly, because the molecules have little kinetic energy and there are few effective collisions. But the enzyme is not denatured. If you warm it up, it works again.
The effect of pH
Every enzyme has an optimum pH where it works fastest.
| Enzyme | Where it works | Optimum pH |
|---|---|---|
| Pepsin (a protease) | Stomach, which is very acidic | About 2 |
| Salivary amylase | Mouth | About 7 (neutral) |
If the pH moves away from the optimum (more acidic or more alkaline):
- The shape of the enzyme changes, so the active site changes shape.
- The substrate does not fit as well, so fewer enzyme-substrate complexes form.
- Activity goes down.
- At a pH far from the optimum, the enzyme is denatured.
Practical: investigating temperature
- Put tubes of starch solution and tubes of amylase in water baths at different temperatures, such as 20, 30, 40, 50 and 60 °C. Leave them for 5 minutes so they reach the right temperature.
- Put one drop of iodine into each dip of a spotting tile.
- Mix the amylase with the starch and start a stopwatch.
- Every 30 seconds, put one drop of the mixture onto a fresh drop of iodine.
- Stop when the iodine stays orange-brown. This means all the starch has been broken down.
- Record the time. A shorter time means the enzyme worked faster.
To make it a fair test, keep these the same: the volume and concentration of starch, the volume and concentration of amylase, and the pH (use a buffer solution).
Practical: investigating pH
Use the same method, but keep the temperature the same (for example, a 37 °C water bath). Change the pH by adding different buffer solutions (for example pH 3, 5, 7, 9 and 11).
Common mistakes
- Saying high temperature "kills" the enzyme. Enzymes are not alive. Say it is denatured.
- Saying the enzyme is denatured at low temperatures. Cold enzymes are only slow. They work again when warmed.
- Saying the substrate is denatured. It is the enzyme that is denatured.
- Forgetting to explain why: always link to the shape of the active site and the fit with the substrate.
- Saying all enzymes have an optimum pH of 7. Pepsin works best at about pH 2.
Exam tips
- When describing a graph, use numbers from it: "activity increases up to 37 °C, then falls quickly and reaches zero at 60 °C."
- To explain the rising part of the graph, use kinetic energy and frequency of effective collisions.
- To explain the falling part, use active site changes shape, substrate no longer fits, and denatured.
- In a planning question, say what you change, what you measure, and what you keep the same.
Next: test yourself with the practice questions below.
The whole topic on one page
Measuring activity
- Substrate goes down
- Product goes up
- Starch: iodine test every 30 s
- Catalase: count oxygen bubbles
Warming up
- More kinetic energy
- More effective collisions
- Faster rate
Optimum
- Fastest activity
- About 37 °C in humans
- Each enzyme has an optimum pH
Too hot or wrong pH
- Active site changes shape
- Substrate no longer fits
- Enzyme is denatured
- Cannot be undone
Cold
- Slow, few collisions
- Not denatured
- Works again when warm
pH examples
- Pepsin: about pH 2
- Amylase: about pH 7
Measuring activity
- Substrate goes down
- Product goes up
- Starch: iodine test every 30 s
- Catalase: count oxygen bubbles
Warming up
- More kinetic energy
- More effective collisions
- Faster rate
Optimum
- Fastest activity
- About 37 °C in humans
- Each enzyme has an optimum pH
Too hot or wrong pH
- Active site changes shape
- Substrate no longer fits
- Enzyme is denatured
- Cannot be undone
Cold
- Slow, few collisions
- Not denatured
- Works again when warm
pH examples
- Pepsin: about pH 2
- Amylase: about pH 7
Flashcards (13 cards)
Say the answer in your head first, then flip. Mark the ones you missed and go through them again.
Keyboard: Space to flip · ← → to move · 1 Again · 2 Got it
Topic 5.2 Practice Quiz (5 Questions)
Answer all 5 multiple-choice questions. Score 5 out of 5 to mark this topic as mastered.
Still stuck? Ask the AI tutor
Ask about anything in topic 5.2. Answers are based on these notes.